  Mitsubishi Chemical Analytech Co., Ltd. as a manufacture, we provide sales & service for Analytical Instruments and Electric Measurement Devices those are valuable for Environmental Analysis, Products Inspection, QC etc.
For environmental Analysis, we recommend our products based on Coulometric Titration for AOX, EOX, POX, Cl and S in Water. For Products Inspection & QC, we support you by Cl, S Analyzer for Petroleum, Petrochemical Products etc.
We also manufacture Sample Prep System for Ion Chromatography that can measure Halogens (Cl, F, Br, I) and Sulfur separately.

 Karl Fischer Moisture Meter  Model CA-200 Series(pdf. 3M 8pages)
   It can modify in Coulometric titration method or Volumetric titration method with combination.
Model CA-200,KF-200,VA-200,VA-210,VA-230,VA-121,VA-122,VG-200,AML-200 and VA-236S
 Model CA-200 Series Video Advertisement
 Portable Karl Fischer Moisture(pdf. 900K 4pages)
 Automatic Titrator  Model GT-200(pdf. 8M 12pages)
  Automatic Potentiometric Titrator with dispenser, sample changer accessories.
 Automatic Quick Furnace  Model AQF-2100H(pdf. 2.4M 8pages)
   Combustion Ion chromatography (C-IC).
   Horizontal Furnace Combustion Type Analyzer.
 Total Chlorine/Sulfur Analyzer   Model TOX-100(pdf. 3.3M 12pages)
   Horizontal Furnace Combustion Type Analyzer,
   Measure TOX,AOX,EOX,POX,TX,TS,TN
   Concentrations from ppb to low % levels.
 Model NSX-2100H(pdf. 3.5M 8pages)
   NEW Elemental Analyzer NSX-2100H, new horizontal furnace system with coulometric detector. New Chlorine analyzer is cost effective solution and has superior cell stability for ppb level titration analysis, and same detector can be used for Sulfur also. NSX-2100H has modular system configuration, various option of sample injectors and other detectors, UVFL Sulfur and Chemiluminescence Nitrogen are also available. This system offer fast and improved performance for optimum plant operation and for catalyst control.
 Model NSX-2100V(pdf. 2.6M 8pages)
  NEW Trace Elemental Analyzer NSX-2100V, new virtical furnace system for in liquid, gas/LPG analysis.
New Chlorine analyzer can be used for cost effective solution and be designed for cell stability for ppb level titration analysis.
NSX-2100V has modular system configuration, various option of sample injector for liquid/gas/LPG available and also other detector can be used as UVFL Sulfur and Chemiluminescence Nitrogen. This system offer fast and improved performance for optimum plant operation and for catalyst control.
 Total Organic Halogen Analyzer (AOX)  Model TOX-100(pdf. 3.3M 12pages)
   Horizontal Furnace Combustion Type Analyzer,
   Measure TOX,AOX,EOX,POX,
   Concentrations from ppb to low % levels.
 Model AOX-200(pdf. 2.1M 4pages)
   Vertical Furnace Combustion Type Analyzer.
 Total Nitrogen Analyzer   Model NSX-2100V(pdf. 2.6M 8pages)
  NEW Trace Elemental Analyzer NSX-2100V, new virtical furnace system for in liquid, gas/LPG analysis.
New Nitrogen analyzer has been improved ppb analysis as to conformed to recent customer requirement. NSX-2100V@has modular system configuration, and various option of sa mple injectorfor liquid/gas/LPG available and also other detector can be used as UVFL Sulfur and Coulometric titration Chlorine. This system offer fast and improved performance for optimum plant operation and for catalyst control.
 Model NSX-2100H(pdf. 3.5M 8pages)
   NEW Trace Elemental Analyzer NSX-2100H, new horizontal furnace system with Chemiluminescence Nitrogen detector. New Nitrogen analyzer has been improved ppb analysis as to conformed to recent customer requirement. NSX-2100H has modular, you can add another detector and sample injector. UVFL Sulfur(simultaneous), Coulometric titration Chlorine, and C-IC absorption module available. This system offer fast and improved performance for optimum plant operation and for catalyst control.
 Trace Sulfur Analyzer   Model NSX-2100V (pdf. 2.6M 8pages)
  NEW Trace Elemental Analyzer NSX-2100V, new virtical furnace system for in liquid, gas/LPG analysis.
New Sulfur analyzer has been improved ppb analysis as to conformed to recent customer requirement. NSX-2100V has modular system configuration, and various option of sample injectorfor liquid/gas/LPG available and also other detector can be used as Chemiluminescence Nitrogen (simultaneous) and Coulometric titration Chlorine. This system offer fast and improved performance for optimum plant operation and for catalyst control.
 Model NSX-2100H(pdf. 3.5M 8pages)
   NEW Trace Elemental Analyzer NSX-2100H, new horizontal furnace with UVFL Sulfur detector. New Sulfur analyzer has been improved ppb analysis as to conformed to recent customer requirement. NSX-2100H has modular system configuration, and various option of sample injectors and detectors can be added, as Chemiluminescence Nitrogen (simultaneous), Coulometric titration Chlorine and C-IC absorption module. This system offer fast and improved performance for optimum plant operation and for catalyst control.
 Resistivity Meter  Lineup Catalogue(pdf. 3.6M 12pages)
   
Low and Hige Resistivity Measurment Meters and Options.
 Loresta GP Model MCP-T600
 Hiresta UP Model MCP-HT450
 Loresta EP Model MCP-T360(pdf. 460K 2pages)
* Company names in asterisk catalogs are old.
We are revising them sequentially
.


Contact
Click Here!
We, MCCAT, support your analysis through our local agents. Please access to our agent in your country with checking a page, gContact ush if necessary.
Although, if youfll not see our agents in your country, please send your e-mail message directly to us. Our e-mail address is also mentioned in the same page.
Itfs our pleasure to supporting you in any time.
We hope youfll enjoy using our new products in the near future.





Mitsubishi Chemical Analytech Co.,Ltd.
Instruments Division
370 ENZO CHIGASAKI,KANAGAWA PREF.253-0084 JAPAN
TELEPHONE: 81-467-86-3864; FACSIMILE: 81-467-86-3862